Up to 70% Water Savings at Taps, Showers etc.
Application
Outlets supplied by water with a minimum pressure of approx. 1 Bar (i.e. pumped/mains water supply, or gravity fed tall buildings).
Function
Point of use regulators designed to provide constant and maximum flow rates at taps and showers etc. irrespective of changes in demand or water pressure fluctuations between 1–10 Bar.
Benefits
• Large water (+ energy) savings
• Even water distribution throughout the site, even at peak demand periods
• Lower capital costs (potential savings from smaller pipework, water heating systems etc.)
• Reduced "peak demand"
• Ideal for retro-fit or new build projects
• Low cost solution. Payback often within months
• Help reduce "back splash" at basins
Combined Isolating Valve and Flow Regulator
|
Order Code: RP/ACC Valve With access port on side of valve to allow removal of flow regulator cartridge (and optional strainer) without draining down system or breaking pipework (picture: opposite), for the purpose of flushing out the system on commisioning or changing the flow regulator cartridge to a higher or lower flow rate as required. Available in 15mm or 22mm sizes and comes with colour coded cap to show the flow rate the valve is set to. Flow rates and colourcoding for both sizes are:
|
||||||
![]() ![]() |
Flow Regulator Insert Circular flow regulator insert (only) for your own valves. Simply fit in to the tap/appliance side of your own compression ended valve. Flow rates for 15mm size exactly as RP/ACC above, however please note flow rates for 22mm size start at 8 Lpm. |
|
![]() ![]() |
Combined Aerator & Flow Regulator No plumbing required to fit. Simply replace existing tap aerator with this unit. Flow rates/colour-coding as follows: |
|
|
Combined CARE Insert (flow straightener) and Flow Regulator Mainly used for medical applications as the laminar flow does not aspirate air into the water. No plumbing required to fit. Simply replace existing tap aerator with this fitting. Flow rates as combined Aerator and Flow Regulator (above). |
|
| Combined Spray and Flow Regulator Mainly used for applications where very low water consumption is required. Pressure compensating from 0.8 Bar– 5 Bar. No plumbing required to fit. Simply replace existing tap aerator with this fitting. Flow rates/colour-coding as follows: | |
![]() ![]() |
½" Shower Flow Regulator Ideally fit this unit at the thermostatic mixing valve end of the flexi-hose. If fixed head shower, unscrew the showerhead, screw the flow regulator in and then re-fit the shower head. No plumbing required to fit. Flow rates/colour-coding as follows: |
|
![]() ![]() |
½" MxF Chrome Tap Tail/Mixer & Flow Regulator
Simply screw on to ½" inlet pipe thread to an Flow rates/colour-coding as follows: |










