Automatic Individual Urinal Flush Controls (up to 80% water savings) |
 |
 |
 |
Each urinal bowl has it's own sensor and solenoid valve, so that only the urinal bowl that gets used gets flushed. Flush occurs immediately after use. |
 |
 |
No cisterns required - water supply can come direct off the mains if you use DC Pipe Interupters. |
 |
 |
No mechanical handles or linkages to break - helps reduce maintenance. |
|
 |
Application: each individual urinal bowl
The sensor is recessed into the wall at about chest
height directly above each urinal bowl, and activates a
solenoid valve to flush the urinal bowl. Flushing will
only occur after the person has finished and walked
away out of sensor range. Adjustable valve open
periods for each flush to suit site requirements.
 |
Only the urinal bowl actually used gets flushed. |
 |
 |
Increased hygiene. |
 |
 |
LargeWater Savings (up to 90%). |
 |
 |
Mains & battery powered units available. |
 |
 |
Hygiene flush when urinals not in use. |
 |
 |
Walking past a sensor will not accidentally flush
urinal as person must be in front of sensor for
minimum of 10 seconds before a flush can be
activated. |
 |
 |
No cisterns required if you use DC pipe interrupters.
Please call to discuss this if required. |
 |
 |
 |
 |
| Mains powered kit |
 |
Battery powered kit |
 |
 |
 |
| SBUFC-M |
 |
SBUFC-B |
 |
 |
|
 |
|
SBUFC(V2)-M mains powered kit.
(c/w stainless steel sensor).
Kit only suitable for water pressure.
0.5 bar to 6 bar water pressure. |
One kit required for each urinal bowl. Each kit c/w: solenoid valve, sensor, control box. (Battery pack or transformer to wire into a fused spur).
Optional low pressure valve available. Optional DC pipe interrupters available. Up to 3 x sensors in a row can be powered from a 3amp fused spur.
 |
 |
 |
PIR Water Saving Controls |
 |
 |
|
Traditional Problem: Uncontrolled banks of urinals are continually
wasting water by flushing all day and all night 365 days per year... even when
the building is empty! A single 9 litre cistern flushing (at a typical rate of)4 times
per hour will consume 315,000 litres of water per year – most of which is totally
wasted and at a cost of about £475 per year based on national average water &
sewerage charge of £1.52 perm³ (1998/99 source OF WAT).
The Solution (and water savings of up to 80%):
A Passive Infra Red
(PIR) sensor fitted near the urinals is wired to a solenoid valve which in turn
controls the water flow to the cistern feeding the urinals. Flushing
only occurs after the urinals have been used (and you can regulate the
maximum number of times per hour the urinals will flush when the gents are
busy). This creates huge water savings by ensuring water is not wasted during
quiet periods, nights, weekends etc. If your water supply is metered then any
water savings equate to financial savings. Meets Byelaws 82 & 83.
|
Automatic "Hygiene Flush": Once every 12 hours when the urinals are not in use for long periods to help prevent traps drying out etc.
No cisterns required: If you use DC pipe interrupters. Please call to discuss this if required.
|
Ceiling Recessed Sensor
|
Ideal for new projects or where vandalism might be a risk.
|
Recessed Sensor Kit
128 x 75 x 85mm

Order code DLM Mains powered kit
Order code DLB Battery powered kit
|
 |
Recessed Sensor Kit
80 x 80 x 50mm

Order code PDLM Mains powered kit
Order code PDLB Battery powered kit
|
 |
|
Surface Mounted Sensor
|
|
Surface Mounted Sensor Kit
120mm W x 100mm H x 45mm D - Available in white ABS box

Order code FMM Mains powered kit
Order code FMB Battery powered kit
|
Each kit comes with: 15mm solenoid valve, PIR sensor & adjustable time controls.Battery powered units come with long life
battery pack. Mains powered units come with separate transformer unit (to be wired to 3A fused spur). Low pressure
solenoid valve available on request.
|
 |

 |